A healthy spinal disc is capable of 3 degrees of rotation and has a force-deflection response that helps to stabilize the spine. Age or trauma can cause the stability of the spine to decrease. Spinal fusion, the current surgical treatment of choice, stabilizes the spine by rigid fixation, reducing spinal mobility at the cost of increased stress at adjacent levels. This paper introduces a compliant mechanism that has the potential to closely mimic the physiological motion profile of the natural spinal disc. Compliant mechanisms have properties that make them well suited for spinal implants that restores the range of motion and the forcedeflection response of the spine. This paper presents an introduction to the biomechanics of the spinal disc, reviews the state of the art in spinal care, and proposes the use of the Flexure-based Bi-Axial Contact-aided (Flex-BAC) compliant mechanism as a spinal arthroplasty device (artificial disc). The Flex-BAC compliant mechanism offers the potential to restore both the kinematics and kinetics of a damaged spinal disc. The disc provides the ability to eliminate wear through rolling. An overview of the device and a preliminary kinematic and kinetic analysis are given.
Skip Nav Destination
ASME 2008 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 3–6, 2008
Brooklyn, New York, USA
Conference Sponsors:
- Design Engineering Division and Computers in Engineering Division
ISBN:
978-0-7918-4326-0
PROCEEDINGS PAPER
A Flexure-Based Bi-Axial Contact-Aided Compliant Mechanism for Spinal Arthroplasty
Peter A. Halverson,
Peter A. Halverson
Brigham Young University, Provo, UT
Search for other works by this author on:
Larry L. Howell,
Larry L. Howell
Brigham Young University, Provo, UT
Search for other works by this author on:
Anton E. Bowden
Anton E. Bowden
Brigham Young University, Provo, UT
Search for other works by this author on:
Peter A. Halverson
Brigham Young University, Provo, UT
Larry L. Howell
Brigham Young University, Provo, UT
Anton E. Bowden
Brigham Young University, Provo, UT
Paper No:
DETC2008-50121, pp. 405-416; 12 pages
Published Online:
July 13, 2009
Citation
Halverson, PA, Howell, LL, & Bowden, AE. "A Flexure-Based Bi-Axial Contact-Aided Compliant Mechanism for Spinal Arthroplasty." Proceedings of the ASME 2008 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 2: 32nd Mechanisms and Robotics Conference, Parts A and B. Brooklyn, New York, USA. August 3–6, 2008. pp. 405-416. ASME. https://doi.org/10.1115/DETC2008-50121
Download citation file:
57
Views
0
Citations
Related Articles
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
A Pseudo-Rigid-Body Model of the Human Spine to Predict Implant-Induced Changes on Motion
J. Mechanisms Robotics (November,2011)
In-vitro Biomechanics of the Cervical Spine: a Systematic Review
J Biomech Eng (January,0001)
Related Chapters
Understanding the Problem
Design and Application of the Worm Gear
Embracing Change Management
Change Management: Concepts and Practice (The Technical Manager's Survival Guides)
A Novel Clustering Approach for Manets Based on Mobility
International Conference on Computer and Computer Intelligence (ICCCI 2011)