The intramedullary canal presence of a stemmed prosthetic component can be expected to change the distribution of stress from the joint loading to the adjacent skeleton. The reconstructed skeletal stiffening that results for relatively rigid prosthetic components can result in periprosthetic stress shielding. The abrupt change in reconstruction stiffness that can occur at the implant stem terminus can be associated with periprosthetic pain. A stem end “clothes pin” slot, intended to make a stem end more flexible, produces a substantially asymmetric and abrupt alteration of stem stiffness. The present work is directed to analyzing ways that the structural stiffness of the terminus region of a prosthetic stem can be controlled to provide a symmetrical transitional region of controllable load transfer to the surrounding bone. It is hypothesized that through implant design, prosthesis-to-bone interface pressure and periprosthetic bone stress levels at a prosthetic stem terminus can be reduced and that this will be associated with a reduced occurrence and severity of “end of stem pain” in a variety of prosthetic applications.
Skip Nav Destination
ASME 2007 Summer Bioengineering Conference
June 20–24, 2007
Keystone, Colorado, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-4798-5
PROCEEDINGS PAPER
Transitional Stiffness Intramedullary Stems to Reduce Periprosthetic Pain
R. D. Crowninshield,
R. D. Crowninshield
Rush Medical College, Chicago, IL
Search for other works by this author on:
W. Paprosky,
W. Paprosky
Rush Medical College, Chicago, IL
Search for other works by this author on:
A. Rosenberg,
A. Rosenberg
Rush Medical College, Chicago, IL
Search for other works by this author on:
A. Stoller
A. Stoller
Zimmer, Inc., Warsaw, IN
Search for other works by this author on:
R. D. Crowninshield
Rush Medical College, Chicago, IL
D. Wentz
Zimmer, Inc., Warsaw, IN
W. Paprosky
Rush Medical College, Chicago, IL
A. Rosenberg
Rush Medical College, Chicago, IL
A. Stoller
Zimmer, Inc., Warsaw, IN
Paper No:
SBC2007-175997, pp. 691-692; 2 pages
Published Online:
March 12, 2014
Citation
Crowninshield, RD, Wentz, D, Paprosky, W, Rosenberg, A, & Stoller, A. "Transitional Stiffness Intramedullary Stems to Reduce Periprosthetic Pain." Proceedings of the ASME 2007 Summer Bioengineering Conference. ASME 2007 Summer Bioengineering Conference. Keystone, Colorado, USA. June 20–24, 2007. pp. 691-692. ASME. https://doi.org/10.1115/SBC2007-175997
Download citation file:
2
Views
0
Citations
Related Proceedings Papers
Related Articles
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
Physically Realizable Three-Dimensional Bone Prosthesis Design With Interpolated Microstructures
J Biomech Eng (March,2017)
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
How the Worm Gear Developed through Time
Design and Application of the Worm Gear
Simple Structural Elements
Introduction to Plastics Engineering