Misalignment between the axes of measurement and the material symmetry axes of bone causes error in anisotropic elastic property measurements. Measurements of Poisson’s ratio were strongly affected by misalignment errors. The mean errors in the measured Young’s moduli were 9.5 and 1.3 percent for cancellous and cortical bone, respectively, at a misalignment angle of 10 degrees. Mean errors of 1.1 and 5.0 percent in the measured shear moduli for cancellous and cortical bone, respectively, were found at a misalignment angle of 10 degrees. Although, cancellous bone tissue was assumed to have orthotropic elastic symmetry, the possibility of the greater symmetry of transverse isotropy was investigated. When the nine orthotropic elastic constants were forced to approximate the five transverse isotropic elastic constants, errors of over 60 percent were introduced. Therefore, it was concluded that cancellous bone is truly orthotropic and not transversely isotropic. A similar but less strong result for cortical bone tissue was obtained.
Skip Nav Destination
Article navigation
August 1988
Research Papers
Errors Induced by Off-Axis Measurement of the Elastic Properties of Bone
C. H. Turner,
C. H. Turner
Department of Biomedical Engineering, Tulane University, New Orleans, LA
Search for other works by this author on:
S. C. Cowin
S. C. Cowin
Department of Biomedical Engineering, Tulane University, New Orleans, LA
Search for other works by this author on:
C. H. Turner
Department of Biomedical Engineering, Tulane University, New Orleans, LA
S. C. Cowin
Department of Biomedical Engineering, Tulane University, New Orleans, LA
J Biomech Eng. Aug 1988, 110(3): 213-215 (3 pages)
Published Online: August 1, 1988
Article history
Received:
May 22, 1987
Revised:
March 28, 1988
Online:
June 12, 2009
Citation
Turner, C. H., and Cowin, S. C. (August 1, 1988). "Errors Induced by Off-Axis Measurement of the Elastic Properties of Bone." ASME. J Biomech Eng. August 1988; 110(3): 213–215. https://doi.org/10.1115/1.3108433
Download citation file:
Get Email Alerts
Related Articles
Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
J Biomech Eng (November,2015)
Further Investigations in Tubesheet Design for a U-Tube Heat Exchanger
J. Pressure Vessel Technol (May,1996)
A Note on the Derivation of Plane-Strain Elastic Green’s Functions for Bimaterial Solids
J. Appl. Mech (November,2009)
Related Proceedings Papers
Related Chapters
Monocrystal-Polycrystal Elastic-Constant Models
Dynamic Elastic Modulus Measurements in Materials
Low Temperature Elastic Properties of Aluminum 5083-0 and Four Ferritic Nickel Steels
Properties of Materials for Liquefied Natural Gas Tankage
The Torsional Failure and Fracture Energy in Shear of Pultruded Rod
Test Methods and Design Allowables for Fibrous Composites: 2nd Volume