Edge-to-edge technique is a surgical procedure for the correction of mitral valve leaflets prolapse by suturing the edge of the prolapsed leaflet to the free edge of the opposing one. Suture presence modifies valve mechanical behavior and orifice flow area in the diastolic phase, when the valve opens and blood flows into the ventricle. In the present work, in order to support identification of potentially critical conditions, a computational procedure is described to evaluate the effects of changing suture length and position in combination with valve size and shape. The procedure is based on finite element method analyses applied to a range of different mitral valves, investigating for each configuration the influence of repair on functional parameters, such as mitral valve orifice area and transvalvular pressure gradient, and on structural parameters, such as stress in the leaflets and stitch tension. This kind of prediction would ideally require a coupled fluid-structural analysis, where the interactions between blood flows and mitral apparatus deformation are simultaneously considered. In the present study, however, an alternative approach is proposed, in which results obtained by purely structural finite element analyses are elaborated and interpreted taking into account the Bernoulli type equations available in literature to describe blood flow through mitral orifice. In this way, the effects of each parameter in terms of orifice flow area, suture loads, and leaflets stresses can be expressed as functions of atrioventricular pressure gradient and then correlated to blood flow rate. Results obtained by using this procedure for different configurations are finally discussed.
Skip Nav Destination
e-mail: andrea.avanzini@ing.unibs.it
Article navigation
June 2008
Research Papers
A Computational Procedure for Prediction of Structural Effects of Edge-to-Edge Repair on Mitral Valve
Andrea Avanzini
Andrea Avanzini
Department of Mechanical and Industrial Engineering,
e-mail: andrea.avanzini@ing.unibs.it
University of Brescia
, Italy, Via Branze 38, 25123 Brescia, Italy
Search for other works by this author on:
Andrea Avanzini
Department of Mechanical and Industrial Engineering,
University of Brescia
, Italy, Via Branze 38, 25123 Brescia, Italye-mail: andrea.avanzini@ing.unibs.it
J Biomech Eng. Jun 2008, 130(3): 031015 (10 pages)
Published Online: May 1, 2008
Article history
Received:
March 27, 2007
Revised:
January 11, 2008
Published:
May 1, 2008
Citation
Avanzini, A. (May 1, 2008). "A Computational Procedure for Prediction of Structural Effects of Edge-to-Edge Repair on Mitral Valve." ASME. J Biomech Eng. June 2008; 130(3): 031015. https://doi.org/10.1115/1.2913235
Download citation file:
Get Email Alerts
Related Articles
A Design Framework of Unloaded Leaflet Shape for the Ovine Pulmonary Valve Single Leaflet Replacement Surgery
J. Med. Devices (June,2011)
Hemodynamic Changes Induced by Pneumoperitoneum and Measured With ECOM
J. Med. Devices (June,2011)
A Method and Apparatus to Simulate Physiologic Right Side Heart Movement in a Fresh Human Cadaver: Pilot Studies
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
mDFA Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition