Little work has been done on the localization of microcracks in bone using acoustic emission. Microcrack localization is useful to study the fracture process in bone and to prevent fractures in patients. Locating microcracks that occur before fracture allows one to predict where fracture will occur if continued stress is applied to the bone. Two source location algorithms were developed to locate microcracks on rectangular bovine bone samples. The first algorithm uses a constant velocity approach which has some difficulty dealing with the anisotropic nature of bone. However, the second algorithm uses an iterative technique to estimate the correct velocity for the acoustic emission source location being located. In tests with simulated microcracks, the constant velocity algorithm achieves a median error of 1.78 mm (IQR 1.51 mm) and the variable velocity algorithm improves this to a median error of 0.70 mm (IQR 0.79 mm). An experiment in which the bone samples were loaded in a three point bend test until they fractured showed a good correlation between the computed location of detected microcracks and where the final fracture occurred. Microcracks can be located on bovine bone samples using acoustic emission with good accuracy and precision.
Skip Nav Destination
Article navigation
January 2013
Research-Article
Hyperbolic Source Location of Crack Related Acoustic Emission in Bone
John Hession,
Gordon Muir
Gordon Muir
Search for other works by this author on:
John O'Toole
e-mail: otoole.pjohn@gmail.com
Leo Creedon
e-mail: creedon.leo@itsligo.ie
John Hession
e-mail: hession.john@itsligo.ie
Gordon Muir
Contributed by the Bioengineering Division of ASME for publication in the Journal of Biomechanical Engineering. Manuscript received April 25, 2012; final manuscript received October 21, 2012; accepted manuscript posted November 28, 2012; published online December 27, 2012. Assoc. Editor: Richard Neptune.
J Biomech Eng. Jan 2013, 135(1): 011006 (9 pages)
Published Online: December 27, 2012
Article history
Received:
April 25, 2012
Revision Received:
October 21, 2012
Accepted:
November 28, 2012
Citation
O'Toole, J., Creedon, L., Hession, J., and Muir, G. (December 27, 2012). "Hyperbolic Source Location of Crack Related Acoustic Emission in Bone." ASME. J Biomech Eng. January 2013; 135(1): 011006. https://doi.org/10.1115/1.4023091
Download citation file:
Get Email Alerts
Cited By
Related Articles
The Tolerance of the Frontal Bone to Blunt Impact
J Biomech Eng (February,2011)
The Tolerance of the Maxilla to Blunt Impact
J Biomech Eng (June,2011)
The Microstructural Origins of Acoustic Emission Signatures Encountered During Fracture Cutting of Bovine Cortical Bone
J. Manuf. Sci. Eng (September,2023)
Accounting for Inclusions and Voids Allows the Prediction of Tensile Fatigue Life of Bone Cement
J Biomech Eng (May,2009)
Related Proceedings Papers
Related Chapters
Experimental Research on Fiber Grating Sensor Acoustic Emission Detection of Rock Material Specimen Failure
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
DEVELOPMENTS IN STRAIN-BASED FRACTURE ASSESSMENTS - A PERSPECTIVE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Hypervelocity Impact Damage Detection in Stiffened Plate by Acoustic Emission
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3