Intervertebral disk (IVD) degeneration is a prevalent health problem that is highly linked to back pain. To understand the disease and tissue response to therapies, ex vivo whole IVD organ culture systems have recently been introduced. The goal of this work was to develop and validate the design of a whole spinal segment culturing system that loads the disk in complex loading similar to the in vivo condition, while preserving the adjacent endplates and vertebral bodies. The complex loading applied to the spinal segment (flexion–extension (FE), bilateral bending, and compression) was achieved with three pneumatic cylinders rigidly attached to a triangular loading platform. A culture container housed the spinal segment and was attached to the loading mechanism, which allowed for loading of the spinal segment. The dynamic bioreactor was able to achieve physiologic loading conditions with 100 N of applied compression and approximately 2–4 N · m of applied torque. The function of the bioreactor was validated through testing of bovine caudal IVDs with intact endplates and vertebral bodies that were isolated within 2 hrs of death and cultured for 14 days. The resulting IVD cell viability following 14 days of loading was much higher than unloaded control IVDs. The loading system accurately mimicked FE, bilateral bending, and compression motions seen during daily activities. The results indicate that this complex dynamic bioreactor may be appropriate for extended preclinical testing of vertebral-mounted spinal devices and therapies.
Skip Nav Destination
Article navigation
June 2016
Technical Briefs
Functional Validation of a Complex Loading Whole Spinal Segment Bioreactor Design
Amanda M. Beatty,
Amanda M. Beatty
Department of Mechanical Engineering,
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: amandabeatty@byu.edu
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: amandabeatty@byu.edu
Search for other works by this author on:
Anton E. Bowden,
Anton E. Bowden
Department of Mechanical Engineering,
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: abowden@byu.edu
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: abowden@byu.edu
Search for other works by this author on:
Laura C. Bridgewater
Laura C. Bridgewater
Department of Microbiology and Molecular Biology,
Brigham Young University,
4007 Life Sciences Building,
Provo, UT 84602
e-mail: laura_bridgewater@byu.edu
Brigham Young University,
4007 Life Sciences Building,
Provo, UT 84602
e-mail: laura_bridgewater@byu.edu
Search for other works by this author on:
Amanda M. Beatty
Department of Mechanical Engineering,
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: amandabeatty@byu.edu
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: amandabeatty@byu.edu
Anton E. Bowden
Department of Mechanical Engineering,
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: abowden@byu.edu
Brigham Young University,
435 Crabtree Building,
Provo, UT 84602
e-mail: abowden@byu.edu
Laura C. Bridgewater
Department of Microbiology and Molecular Biology,
Brigham Young University,
4007 Life Sciences Building,
Provo, UT 84602
e-mail: laura_bridgewater@byu.edu
Brigham Young University,
4007 Life Sciences Building,
Provo, UT 84602
e-mail: laura_bridgewater@byu.edu
1Corresponding author.
Manuscript received October 27, 2015; final manuscript received April 29, 2016; published online May 11, 2016. Assoc. Editor: James C. Iatridis.
J Biomech Eng. Jun 2016, 138(6): 064501 (4 pages)
Published Online: May 11, 2016
Article history
Received:
October 27, 2015
Revised:
April 29, 2016
Citation
Beatty, A. M., Bowden, A. E., and Bridgewater, L. C. (May 11, 2016). "Functional Validation of a Complex Loading Whole Spinal Segment Bioreactor Design." ASME. J Biomech Eng. June 2016; 138(6): 064501. https://doi.org/10.1115/1.4033546
Download citation file:
Get Email Alerts
Cited By
Development of a Strain-Based Model to Predict Eviscerated Thoracic Response From Dynamic Individual Rib Tests
J Biomech Eng (October 2022)
Related Articles
The Effects of Helmet Weight on Hybrid III Head and Neck Responses by Comparing Unhelmeted and Helmeted Impacts
J Biomech Eng (October,2016)
2016 Editors' Choice Papers
J Biomech Eng (February,2017)
Cellular Response to Cyclic Compression of Tissue Engineered Intervertebral Disk Constructs Composed of Electrospun Polycaprolactone
J Biomech Eng (June,2018)
Applying a Hybrid Experimental-Computational Technique to Study Elbow Joint Ligamentous Stabilizers
J Biomech Eng (June,2018)
Related Proceedings Papers
Related Chapters
Interaction between fluid flow and microbial cells: importance of the operating scale
GFP Whole Cell Microbial Biosensors: Scale-up and Scale-down Effects on Biopharmaceutical Processes
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Estimating Resilient Modulus Using Neural Network Models
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17