Ankle prostheses are limb replacement solutions that provide functional performance for transtibial (below-knee) amputees. An estimated 623,000 major transtibial amputations were performed in the U.S. in 2005 [1]. Having a functional limb replacement that the amputee feels physically and socially comfortable wearing significantly improves his or her quality of life [2]. Most commercially available ankle prostheses are passive devices that do not have actuators or batteries to provide powered push-off at the ankle. Without push-off at the ankle, the amputee relies primarily on his or her intact limb for propulsion. The natural ankle performs net rotational work, but the passive prosthesis is characterized by energy dissipation. This contrasting behavior produces asymmetric gait (walking pattern). Active prostheses with motors and batteries can produce powered push-off, but tend to be bulky and expensive. Collins and Kuo [3] developed a passive prosthesis that demonstrates push-off by storing...
Skip Nav Destination
Article navigation
September 2015
Technical Briefs
Evaluation of a Two Degree of Freedom Passive Ankle Prosthesis With Powered Push-Off1
Jacob J. Rice,
Jacob J. Rice
Department of Mechanical Engineering,
Marquette University
,Milwaukee, WI 53233
Search for other works by this author on:
Joseph M. Schimmels
Joseph M. Schimmels
Department of Mechanical Engineering,
Marquette University
,Milwaukee, WI 53233
Search for other works by this author on:
Jacob J. Rice
Department of Mechanical Engineering,
Marquette University
,Milwaukee, WI 53233
Joseph M. Schimmels
Department of Mechanical Engineering,
Marquette University
,Milwaukee, WI 53233
DOI: 10.1115/1.4030551
Manuscript received March 3, 2015; final manuscript received March 17, 2015; published online July 16, 2015. Editor: Arthur Erdman.
J. Med. Devices. Sep 2015, 9(3): 030915 (2 pages)
Published Online: September 1, 2015
Article history
Received:
March 3, 2015
Revision Received:
March 17, 2015
Online:
July 16, 2015
Citation
Rice, J. J., and Schimmels, J. M. (September 1, 2015). "Evaluation of a Two Degree of Freedom Passive Ankle Prosthesis With Powered Push-Off." ASME. J. Med. Devices. September 2015; 9(3): 030915. https://doi.org/10.1115/1.4030551
Download citation file:
Get Email Alerts
Cited By
Stakeholders, Prototypes, and Settings of Front-End Medical Device Design Activities
J. Med. Devices (September 2022)
DynaRing: A Patient-Specific Mitral Annuloplasty Ring With Selective Stiffness Segments
J. Med. Devices (September 2022)
Scale Effects on Performance of BLDC Micromotors for Internal Biomedical Applications: A Finite Element Analysis
J. Med. Devices (September 2022)
Elliptical Trainer Redesign to Diversify Muscles Recruitment
J. Med. Devices
Related Articles
Design and Evaluation of a Passive Ankle Prosthesis With Powered Push-Off
J. Mechanisms Robotics (April,2016)
Design of Lower Limb Prosthesis Transverse Plane Adaptor With Variable Stiffness
J. Med. Devices (September,2015)
The Effects of the Inertial Properties of Above-Knee Prostheses on Optimal Stiffness, Damping, and Engagement Parameters of Passive Prosthetic Knees
J Biomech Eng (December,2016)
A General Modeling Methodology for the Quasistatic Behavior of Spiral Torsion Springs
J. Mech. Des (January,2021)
Related Proceedings Papers
Related Chapters
Understanding the Problem
Design and Application of the Worm Gear
An Adaptive Fuzzy Control for a Multi-Degree-of-Freedom System
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Axially Loaded Members
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range