Objective: To optimize the assessment of muscle weakness in critically ill patients in the intensive care unit (ICU) by development non-invasive, reproducible assessment devices and application protocols. Methods: For over we evaluated weakness in ICU patients by employing a prototype non-invasive muscle force assessment system. We determined peak torques, peak rates of torque development and decay of the ankle dorsiflexors after supramaximal peroneal nerve stimulation. We continue to test modifications of our devices (i.e. different stabilizing boots, extendable leg support systems, electrodes) so to optimize this important clinical assessment. Results: Measurements were performed in over 30 severely ill adult patients. During their illnesses, one observed dramatic reductions in stimulated torques, and during the recovery period, values increased to 70–80% of initial values. In those patients who died, the values continuously decreased until death. Throughout these investigations, several technical problems arose: i) the current device could not be used on patients in a prone position; ii) the mechanism used to adjust and lock ankle slipped; iii) edema made nerve stimulation difficult (altered skin conductance and difficult to maintain electrode position); iv) device was bulky for positioning (e.g., weight), and∕or v) stimulus parameters could not be readily adjusted. Discussion: Stimulated muscle force assessment can be used to study ICU patients’ forces. Nevertheless, next generation force assessment systems should be smaller, lighter, more portable, with a simple angle adjustment means, easier to use with a computer-controlled stimulator and include EMG recordings.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Methodologies for Performing Non-Invasive Stimulated Muscle Force Assessment in Critically Ill Patients
H. F. Ginz,
H. F. Ginz
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, Switzerland
Search for other works by this author on:
P. A. Iaizzo,
P. A. Iaizzo
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, Switzerland
Search for other works by this author on:
A. Urwyler
A. Urwyler
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, Switzerland
Search for other works by this author on:
H. F. Ginz
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, Switzerland
P. A. Iaizzo
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, Switzerland
A. Urwyler
Department of Anaesthesia,
County Hospital
, 79539 Loerrach, Germany; Department of Anaesthesia, University of Basel Hospital
, 4031 Basel, SwitzerlandJ. Med. Devices. Jun 2008, 2(2): 027519 (1 pages)
Published Online: June 11, 2008
Article history
Published:
June 11, 2008
Citation
Ginz, H. F., Iaizzo, P. A., and Urwyler, A. (June 11, 2008). "Methodologies for Performing Non-Invasive Stimulated Muscle Force Assessment in Critically Ill Patients." ASME. J. Med. Devices. June 2008; 2(2): 027519. https://doi.org/10.1115/1.2936209
Download citation file:
331
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Ambulatory Device for Urinary Incontinence Detection in Female Athletes
J. Med. Devices (June,2009)
Design of a Pressure Measuring Syringe
J. Med. Devices (June,2010)
Cerebrospinal Fluid Volume Monitoring for Hydrocephalus Therapy
J. Med. Devices (June,2011)
A Minimally Invasive Device for Continuous Glucose Monitoring in Infants
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
A Review for Feature Extraction of EMG Signal Processing
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)
Classification of Electromyogram Signal for Control of Robotic Gripper
International Conference on Computer Engineering and Technology, 3rd (ICCET 2011)
Modeling and Classification for Uterine EMG Signals Using Autoregressive Model
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16