1-20 of 118
Keywords: biomechanics
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. March 2019, 13(1): 014502.
Paper No: MED-18-1042
Published Online: November 19, 2018
... 2018 finite element analysis needle biopsy biomechanics Needle biopsy is a common minimally invasive procedure to extract tissue samples for diagnosis of cancer or other disease [ 1 – 3 ]. So far, several needle biopsy devices have been studied in clinical applications [ 4 , 5 ]. 3...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2013, 7(4): 041002.
Paper No: MED-10-1062
Published Online: September 24, 2013
...” ball tip probe may improve assessment of the strength of pedicle screw purchase. bone mineral density assessment screw pull-out strength biomechanics Failure of the pedicle screw at the screw-bone interface is a common clinical problem, particularly in the setting of osteoporosis...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. September 2013, 7(3): 034502.
Paper No: MED-12-1075
Published Online: July 3, 2013
...) and enhanced fidelity that to date have not been fully utilized. Previous robotic efforts in spine biomechanics have largely been limited to pure displacement control methods and slow quasi-static hybrid control approaches incorporating only one motion segment unit (MSU). The ability to program and selectively...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2012, 6(4): 045004.
Published Online: November 21, 2012
... cruciate ligament ligament reconstruction ligament prosthesis artificial ligament synthetic ligament orthopedic surgery biomechanics The anterior cruciate ligament, one of the four major ligaments in the knee, is a critical component for the maintenance of proper tibiofemoral orientation...
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041007.
Published Online: November 28, 2011
.... 25 04 2011 12 09 2011 28 11 2011 28 11 2011 biomechanics biomedical optical imaging cardiology catheters diseases patient rehabilitation patient treatment physiological models prosthetics heart cardiac device CHF DCCD CSD Congestive heart failure...
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041008.
Published Online: November 28, 2011
... – 2859 . 2 Taber , L. A. , 2001 , “ Biomechanics of Cardiovascular Development ,” Annu. Rev. Biomed. Eng. , 3 , pp. 1 – 25 . 10.1146/annurev.bioeng.3.1.1 3 Humphrey , J. D. , 2002 , “Cardiovascular Solid Mechanics: Cells, Tissues, and Organs,” New York , Springer , pp...
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041006.
Published Online: November 15, 2011
... ), pp. 2367 – 2383 . 10.1089/ten.2006.12.2367 2 Butler , D. L. , Goldstein , S. A. , and Guilak , F. , 2000 , “ Functional Tissue Engineering: The Role of Biomechanics ,” J Biomech Eng. , 122 ( 6 ), pp. 570 – 575 . 10.1115/1.1318906 3 Lujann , T. J. , Wirtz...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2011, 5(4): 044504.
Published Online: November 15, 2011
... systems. 29 03 2011 02 09 2011 15 11 2011 15 11 2011 biomechanics biomembranes cellular biophysics diseases eye geometry physiological models vision Retinal diseases such as age-related macular degeneration, diabetic retinopathy, and retinal vein occlusion (RVO...
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041004.
Published Online: November 14, 2011
... the clinic. An automatic variable rate device could improve limb lengthening. 06 04 2011 04 10 2011 14 11 2011 biological tissues biomechanics biomedical equipment bone cellular biophysics data loggers orthopaedics real-time systems surgery limb lengthening distraction...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2011, 5(4): 044501.
Published Online: November 7, 2011
.../j.injury.2003.09.026 17 Miller , D. L. , and Goswami , T. , 2007 , “ A Review of Locking Compression Plate Biomechanics and Their Advantages as Internal Fixators in Fracture Healing ,” Clin. Biomech. , 22 ( 10 ), pp. 1049 – 1062 . 10.1016/j.clinbiomech.2007.08.004 18 Wagner...
Journal Articles
Article Type: Design Innovations
J. Med. Devices. September 2011, 5(3): 035001.
Published Online: August 30, 2011
... serve as a simplistic and cost effective alternative for PDA occlusion. 15 04 2010 07 10 2010 30 08 2011 30 08 2011 adhesion biomechanics biomedical electronics biomedical equipment biomedical imaging blood blood vessels cardiology cellular biophysics diseases ducts...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. September 2011, 5(3): 034502.
Published Online: August 18, 2011
... 2011 08 06 2011 18 08 2011 18 08 2011 biomechanics biomedical equipment bone drug delivery systems elastic moduli fracture toughness hardness neurophysiology orthopaedics physiological models prosthetics skin microneedle biomicroneedle transdermal drug delivery...
Journal Articles
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031006.
Published Online: August 15, 2011
... 2011 15 08 2011 biomechanics biomedical equipment robots A growing number of today’s robots are meant for physical interaction with humans. Humanoid robots shake hands and dual-manipulate objects, haptic robots simulate textures and environments, medical robots improve diagnostics...
Journal Articles
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031005.
Published Online: August 8, 2011
... to validate the effectiveness of the endoscopy sheath. 06 12 2010 27 05 2011 08 08 2011 08 08 2011 biological organs biomechanics biomedical education endoscopes force measurement force sensors patient diagnosis training Endoscopy is a minimally invasive procedure...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027536.
Published Online: June 15, 2011
...Rong Fan; Christopher Hobson; Ahmed Bayoumi; John Mayer; William Wagner; Michael S. Sacks 15 06 2011 15 06 2011 biomechanics biomedical materials deformation elasticity finite element analysis haemodynamics medical disorders paediatrics prosthetics surgery tissue...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027539.
Published Online: June 15, 2011
...Stephen Howard; Cory Kasprzak; Chris Rolfes; Paul A. Iaizzo 15 06 2011 15 06 2011 biomechanics biomedical materials blood vessels cardiovascular system catheters surgery Clinical access to the left atrium and/or to the left ventricle for medical device delivery, from...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027527.
Published Online: June 14, 2011
...Oliver Bandschapp; Charles Soule; Paul A. Iaizzo 14 06 2011 14 06 2011 biomechanics electromyography force measurement medical disorders neuromuscular stimulation proteins Myotonic dystrophy is a dominantly inherited disorder characterized by myotonia and delayed muscle...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027532.
Published Online: June 14, 2011
...Alex Ryan; George Mallin; Paul A. Iaizzo 14 06 2011 14 06 2011 biomechanics cardiovascular system catheters haemodynamics haemorheology In vivo animal models have been and remain the “gold standard” for medical device testing. However, these models sometimes present...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027525.
Published Online: June 14, 2011
... understandings for the design of force control algorithms to automate robotic cutting of bio-materials. biomechanics bone cutting finite element analysis food products food technology fracture industrial robots 14 06 2011 14 06 2011 2011 American Society of Mechanical Engineers ...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027519.
Published Online: June 13, 2011
...Eric A. Nickel; Andrew Hansen; Steven A. Gard 13 06 2011 13 06 2011 biomechanics prosthetics wear The anatomical ankle is capable of providing adaptation to sloped surfaces, a function that is unavailable in most traditional lower limb prostheses. Commercially available...