The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.
Skip Nav Destination
ravikfme@iitr.ernet.in
Article navigation
December 2009
Research Papers
An Experimental Study of the Flow of R-407C in an Adiabatic Spiral Capillary Tube
M. K. Mittal,
M. K. Mittal
Department of Mechanical and Industrial Engineering,
Indian Institute of Technology Roorkee
, Roorkee 247667, India
Search for other works by this author on:
R. Kumar,
R. Kumar
Department of Mechanical and Industrial Engineering,
ravikfme@iitr.ernet.in
Indian Institute of Technology Roorkee
, Roorkee 247667, India
Search for other works by this author on:
A. Gupta
A. Gupta
Department of Mechanical and Industrial Engineering,
Indian Institute of Technology Roorkee
, Roorkee 247667, India
Search for other works by this author on:
M. K. Mittal
Department of Mechanical and Industrial Engineering,
Indian Institute of Technology Roorkee
, Roorkee 247667, India
R. Kumar
Department of Mechanical and Industrial Engineering,
Indian Institute of Technology Roorkee
, Roorkee 247667, Indiaravikfme@iitr.ernet.in
A. Gupta
Department of Mechanical and Industrial Engineering,
Indian Institute of Technology Roorkee
, Roorkee 247667, IndiaJ. Thermal Sci. Eng. Appl. Dec 2009, 1(4): 041003 (8 pages)
Published Online: May 19, 2010
Article history
Received:
December 11, 2009
Revised:
March 16, 2010
Online:
May 19, 2010
Published:
May 19, 2010
Citation
Mittal, M. K., Kumar, R., and Gupta, A. (May 19, 2010). "An Experimental Study of the Flow of R-407C in an Adiabatic Spiral Capillary Tube." ASME. J. Thermal Sci. Eng. Appl. December 2009; 1(4): 041003. https://doi.org/10.1115/1.4001484
Download citation file:
32
Views
0
Citations
Get Email Alerts
Cited By
Numerical Study of Double-Jet Film Cooling on a Semi-Cylindrical Leading Edge
J. Thermal Sci. Eng. Appl
Related Articles
Water-Heated Pool Boiling of Different Refrigerants on the Outside Surface of a Horizontal Smooth Tube
J. Heat Transfer (February,2012)
Modeling of Pressure Drop During Condensation in Circular and Noncircular Microchannels
J. Fluids Eng (January,2009)
Simulation and Experimental Analysis of a Solar Driven Absorption Chiller With Partially Wetted Evaporator
J. Sol. Energy Eng (February,2010)
Related Proceedings Papers
Related Chapters
A Method Based on the Fluctuation of the Temperature Difference to Select the Zeotropic Refrigerant Mixture in the Air-Conditioning Condition
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
A Study on the Refrigerant Charge Quantity of Ground Source Heat Pump System
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Techniques to Reduce Exchanger or System Cost
Heat Exchanger Engineering Techniques