Electromechanical actuators exploit the Lorentz force law to convert electrical energy into rotational or linear mechanical energy. In these electromagnetically induced motions, the electrical current flows through wires that are rigid, and consequently, the types of motion generated are limited. Recent advances in preparing liquid metal alloys permit wires that are flexible. Such wires have been used to fabricate various forms of flexible connections, but very little has been done to use liquid metal as an actuator. In this paper, we propose and have tested a new type of motor using liquid metal conductors in which radial (or breathing) modes are activated.

References

1.
Post
,
E. R.
,
Orth
,
M.
,
Russo
,
P.
, and
Gershenfeld
,
N.
,
2000
, “
E-Broidery: Design and Fabrication of Textile-Based Computing
,”
IBM Syst. J.
,
39
(
3–4
), pp.
840
860
.
2.
Lacour
,
S. P.
,
Wagner
,
S.
,
Huang
,
Z.
, and
Suo
,
Z.
,
2003
, “
Stretchable Gold Conductors on Elastomeric Substrates
,”
Appl. Phys. Lett.
,
82
(
15
), pp.
2404
2406
.
3.
Gray
,
D. S.
,
Tien
,
J.
, and
Chen
,
C. S.
,
2004
, “
High‐Conductivity Elastomeric Electronics
,”
Adv. Mater.
,
16
(
5
), pp.
393
397
.
4.
Siegel
,
A. C.
,
Bruzewicz
,
D. A.
,
Weibel
,
D. B.
, and
Whitesides
,
G. M.
,
2007
, “
Microsolidics: Fabrication of Three‐Dimensional Metallic Microstructures in Poly (Dimethylsiloxane)
,”
Adv. Mater.
,
19
(
5
), pp.
727
733
.
5.
Dickey
,
M. D.
,
Chiechi
,
R. C.
,
Larsen
,
R. J.
,
Weiss
,
E. A.
,
Weitz
,
D. A.
, and
Whitesides
,
G. M.
,
2008
, “
Eutectic Gallium‐Indium (EGaIn): A Liquid Metal Alloy for the Formation of Stable Structures in Microchannels at Room Temperature
,”
Adv. Funct. Mater.
,
18
(
7
), pp.
1097
1104
.
6.
Haynes
,
W. M.
,
2014
,
CRC Handbook of Chemistry and Physics
,
CRC Press
, Taylor & Francis Group, Boca Raton, FL.
7.
Knoblauch
,
M.
,
Hibberd
,
J. M.
,
Gray
,
J. C.
, and
van Bel
,
A. J.
,
1999
, “
A Galinstan Expansion Femtosyringe for Microinjection of Eukaryotic Organelles and Prokaryotes
,”
Nat. Biotechnol.
,
17
(
9
), pp. 906–909.
8.
Hong
,
S. Y.
,
Yoon
,
J.
,
Jin
,
S. W.
,
Lim
,
Y.
,
Lee
,
S.-J.
,
Zi
,
G.
, and
Ha
,
J. S.
,
2014
, “
High-Density, Stretchable, All-Solid-State Microsupercapacitor Arrays
,”
ACS Nano
,
8
(
9
), pp.
8844
8855
.
9.
Yoon
,
J.
,
Hong
,
S. Y.
,
Lim
,
Y.
,
Lee
,
S. J.
,
Zi
,
G.
, and
Ha
,
J. S.
,
2014
, “
Design and Fabrication of Novel Stretchable Device Arrays on a Deformable Polymer Substrate With Embedded Liquid‐Metal Interconnections
,”
Adv. Mater.
,
26
(
38
), pp.
6580
6586
.
10.
Lim
,
Y.
,
Yoon
,
J.
,
Yun
,
J.
,
Kim
,
D.
,
Hong
,
S. Y.
,
Lee
,
S.-J.
,
Zi
,
G.
, and
Ha
,
J. S.
,
2014
, “
Biaxially Stretchable, Integrated Array of High Performance Microsupercapacitors
,”
ACS Nano
,
8
(
11
), pp.
11639
11650
.
11.
Lazarus
,
N.
,
Meyer
,
C.
,
Bedair
,
S.
,
Nochetto
,
H.
, and
Kierzewski
,
I.
,
2014
, “
Multilayer Liquid Metal Stretchable Inductors
,”
Smart Mater. Struct.
,
23
(
8
), p.
085036
.
12.
Lazarus
,
N.
,
Meyer
,
C.
, and
Turner
,
W.
,
2015
, “
A Microfluidic Wireless Power System
,”
RSC Adv.
,
5
(
96
), pp.
78695
78700
.
13.
Jin
,
S. W.
,
Park
,
J.
,
Hong
,
S. Y.
,
Park
,
H.
,
Jeong
,
Y. R.
,
Park
,
J.
,
Lee
,
S.-S.
, and
Ha
,
J. S.
,
2015
, “
Stretchable Loudspeaker Using Liquid Metal Microchannel
,”
Sci. Rep.
,
5
(
1
), pp. 1–12.
14.
Park
,
Y.-L.
,
Chen
,
B.-R.
, and
Wood
,
R. J.
,
2012
, “
Design and Fabrication of Soft Artificial Skin Using Embedded Microchannels and Liquid Conductors
,”
IEEE Sens. J.
,
12
(
8
), pp.
2711
2718
.
15.
Kazem
,
N.
,
Hellebrekers
,
T.
, and
Majidi
,
C.
,
2017
, “
Soft Multifunctional Composites and Emulsions With Liquid Metals
,”
Adv. Mater.
,
29
(27), p. 14.
16.
So
,
J. H.
,
Thelen
,
J.
,
Qusba
,
A.
,
Hayes
,
G. J.
,
Lazzi
,
G.
, and
Dickey
,
M. D.
,
2009
, “
Reversibly Deformable and Mechanically Tunable Fluidic Antennas
,”
Adv. Funct. Mater.
,
19
(
22
), pp.
3632
3637
.
17.
Gent
,
A. N.
,
1958
, “
On the Relation Between Indentation Hardness and Young's Modulus
,”
Rubber Chem. Technol.
,
31
(
4
), pp.
896
906
.
18.
Farzbod
,
F.
,
2013
, “
Resonant Ultrasound Spectroscopy for a Sample With Cantilever Boundary Condition Using Rayleigh-Ritz Method
,”
J. Appl. Phys.
,
114
(
2
), p.
024902
.
You do not currently have access to this content.